Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
1.
Sensors (Basel) ; 24(7)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38610443

RESUMO

The present work proposes a comprehensive metaheuristic methodology for the development of a medical robot for the upper limb rehabilitation, which includes the topological optimization of the device, kinematic models (5 DOF), human-robot interface, control and experimental tests. This methodology applies two cutting-edge triads: (1) the three points of view in engineering design (client, designer and community) and (2) the triad formed by three pillars of Industry 4.0 (autonomous machines and systems, additive manufacturing and simulation of virtual environments). By applying the proposed procedure, a robotic mechanism was obtained with a reduction of more than 40% of its initial weight and a human-robot interface with three modes of operation and a biomechanically viable kinematic model for humans. The digital twin instance and its evaluation through therapeutic routines with and without disturbances was assessed; the average RMSEs obtained were 0.08 rad and 0.11 rad, respectively. The proposed methodology is applicable to any medical robot, providing a versatile and effective solution for optimizing the design and development of healthcare devices. It adopts an innovative and scalable approach to enhance their processes.


Assuntos
Exoesqueleto Energizado , Robótica , Humanos , Comércio , Simulação por Computador , Engenharia
2.
Wearable Technol ; 5: e3, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38486863

RESUMO

Transcutaneous spinal cord stimulation (TSCS) is gaining popularity as a noninvasive alternative to epidural stimulation. However, there is still much to learn about its effects and utility in assisting recovery of motor control. In this study, we applied TSCS to healthy subjects concurrently performing a functional training task to study its effects during a training intervention. We first carried out neurophysiological tests to characterize the H-reflex, H-reflex recovery, and posterior root muscle reflex thresholds, and then conducted balance tests, first without TSCS and then with TSCS. Balance tests included trunk perturbations in forward, backward, left, and right directions, and subjects' balance was characterized by their response to force perturbations. A balance training task involved the subjects playing a catch-and-throw game in virtual reality (VR) while receiving trunk perturbations and TSCS. Balance tests with and without TSCS were conducted after the VR training to measure subjects' post-training balance characteristics and then neurophysiological tests were carried out again. Statistical comparisons using t-tests between the balance and neurophysiological data collected before and after the VR training intervention found that the immediate effect of TSCS was to increase muscle activity during forward perturbations and to reduce balance performance in that direction. Muscle activity decreased after training and even more once TSCS was turned off. We thus observed an interaction of effects where TSCS increased muscle activity while the physical training decreased it.

3.
IEEE Robot Autom Lett ; 9(3): 2104-2111, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38313832

RESUMO

Lower-limb wearable robots designed to assist people in everyday activities must reliably recover from any momentary confusion about what the user is doing. Such confusion might arise from momentary sensor failure, collision with an obstacle, losing track of gait due to an out-of-distribution stride, etc. Systems that infer a user's walking condition from angle measurements using Bayesian filters (e.g., extended Kalman filters) have been shown to accurately track gait across a range of activities. However, due to the fundamental problem structure and assumptions of Bayesian filter implementations, such estimators risk becoming 'lost' with little hope of a quick recovery. In this paper, we 1) introduce a Monte Carlo-based metric to quantify the robustness of pattern-tracking gait estimators, 2) propose strategies for improving tracking robustness, and 3) systematically evaluate them against this new metric using a publicly available gait biomechanics dataset. Our results, aggregating 2,700 trials of simulated walking of 10 able-bodied subjects under random perturbations, suggest that drastic improvements in robustness (from 8.9% to 99%) are possible using relatively simple modifications to the estimation process without noticeably degrading estimator accuracy.

4.
J Neuroeng Rehabil ; 21(1): 22, 2024 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-38342919

RESUMO

Exoskeleton-aided active rehabilitation is a process that requires sensing and acting upon the motion intentions of the user. Typically, force sensors are used for this. However, they increase the weight and cost of these wearable devices. This paper presents the methodology for detecting users' intentions only with encoders integrated with the drives. It is unique compared to other algorithms, as enables active kinesiotherapy while adding no sensory systems. The method is based on comparing the measured motion with the one computed with the idealised model of the multibody system. The investigation assesses the method's performance and its robustness to model and measurement inaccuracies, as well as patients' unintended motions. Moreover, the PID parameters are selected to provide the optimal regulation based on the dynamics requirements. The research proves the presented concept of the control approach. For all the tests with the final settings, the system reacts to a change in the user's intention below one second and minimises the changes in proportion between the system's acceleration and the generated user's joint torque. The results are comparable to those obtained by EMG-based systems and significantly better than low-cost force sensors.


Assuntos
Exoesqueleto Energizado , Robótica , Humanos , Extremidade Superior/fisiologia , Algoritmos , Simulação por Computador
5.
Sensors (Basel) ; 24(4)2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38400205

RESUMO

The utilization of robotic systems in upper limb rehabilitation has shown promising results in aiding individuals with motor impairments. This research introduces an innovative approach to enhance the efficiency and adaptability of upper limb exoskeleton robot-assisted rehabilitation through the development of an optimized stimulation control system (OSCS). The proposed OSCS integrates a fuzzy logic-based pain detection approach designed to accurately assess and respond to the patient's pain threshold during rehabilitation sessions. By employing fuzzy logic algorithms, the system dynamically adjusts the stimulation levels and control parameters of the exoskeleton, ensuring personalized and optimized rehabilitation protocols. This research conducts comprehensive evaluations, including simulation studies and clinical trials, to validate the OSCS's efficacy in improving rehabilitation outcomes while prioritizing patient comfort and safety. The findings demonstrate the potential of the OSCS to revolutionize upper limb exoskeleton-assisted rehabilitation by offering a customizable and adaptive framework tailored to individual patient needs, thereby advancing the field of robotic-assisted rehabilitation.


Assuntos
Exoesqueleto Energizado , Robótica , Humanos , Lógica Fuzzy , Extremidade Superior/fisiologia , Dor
6.
Front Rehabil Sci ; 5: 1246773, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38343790

RESUMO

Lower limb rehabilitation is essential for recovery post-injury, stroke, or surgery, improving functional mobility and quality of life. Traditional therapy, dependent on therapists' expertise, faces challenges that are addressed by rehabilitation robotics. In the domain of lower limb rehabilitation, machine learning is progressively manifesting its capabilities in high personalization and data-driven approaches, gradually transforming methods of optimizing treatment protocols and predicting rehabilitation outcomes. However, this evolution faces obstacles, including model interpretability, economic hurdles, and regulatory constraints. This review explores the synergy between machine learning and robotic-assisted lower limb rehabilitation, summarizing scientific literature and highlighting various models, data, and domains. Challenges are critically addressed, and future directions proposed for more effective clinical integration. Emphasis is placed on upcoming applications such as Virtual Reality and the potential of deep learning in refining rehabilitation training. This examination aims to provide insights into the evolving landscape, spotlighting the potential of machine learning in rehabilitation robotics and encouraging balanced exploration of current challenges and future opportunities.

7.
Bioengineering (Basel) ; 10(12)2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38135989

RESUMO

This study characterizes the effects of a postural training program on balance and muscle control strategies in a virtual reality (VR) environment. The Robotic Upright Stand Trainer (RobUST), which applies perturbative forces on the trunk and assistive forces on the pelvis, was used to deliver perturbation-based balance training (PBT) in a sample of 10 healthy participants. The VR task consisted of catching, aiming, and throwing a ball at a target. All participants received trunk perturbations during the VR task with forces tailored to the participant's maximum tolerance. A subgroup of these participants additionally received assistive forces at the pelvis during training. Postural kinematics were calculated before and after RobUST training, including (i) maximum perturbation force tolerated, (ii) center of pressure (COP) and pelvic excursions, (iii) postural muscle activations (EMG), and (iv) postural control strategies (the ankle and hip strategies). We observed an improvement in the maximum perturbation force and postural stability area in both groups and decreases in muscle activity. The behavior of the two groups differed for perturbations in the posterior direction where the unassisted group moved towards greater use of the hip strategy. In addition, the assisted group changed towards a lower margin of stability and higher pelvic excursion. We show that training with force assistance leads to a reactive balance strategy that permits pelvic excursion but that is efficient at restoring balance from displaced positions while training without assistance leads to reactive balance strategies that restrain pelvic excursion. Patient populations can benefit from a platform that encourages greater use of their range of motion.

9.
Front Pediatr ; 11: 1153841, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37928351

RESUMO

Infants born pre-term are at an increased risk for developmental, behavioral, and motor delay and subsequent disability. When these problems are detected early, clinical intervention can be effective at improving functional outcomes. Current methods of early clinical assessment are resource intensive, require extensive training, and do not always capture infants' behavior in natural play environments. We developed the Play and Neuro Development Assessment (PANDA) Gym, an affordable, mechatronic, sensor-based play environment that can be used outside clinical settings to capture infant visual and motor behavior. Using a set of classification codes developed from the literature, we analyzed videos from 24 pre-term and full-term infants as they played with each of three robotic toys designed to elicit different types of interactions-a lion, an orangutan, and an elephant. We manually coded for frequency and duration of toy interactions such as kicking, grasping, touching, and gazing. Pre-term infants gazed at the toys with similar frequency as full-term infants, but infants born full-term physically engaged more frequently and for longer durations with the robotic toys than infants born pre-term. While we showed we could detect differences between full-term and pre-term infants, further work is needed to determine whether differences seen were primarily due to age, developmental delays, or a combination.

10.
Sensors (Basel) ; 23(21)2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37960649

RESUMO

Due to the growth of sensor technology, more affordable integrated circuits, and connectivity technologies, the usage of wearable equipment and sensing devices for monitoring physical activities, whether for wellness, sports monitoring, or medical rehabilitation, has exploded. The current literature review was performed between October 2022 and February 2023 using PubMed, Web of Science, and Scopus in accordance with P.R.I.S.M.A. criteria. The screening phase resulted in the exclusion of 69 articles that did not fit the themes developed in all subchapters of the study, 41 articles that dealt exclusively with rehabilitation and orthopaedics, 28 articles whose abstracts were not visible, and 10 articles that dealt exclusively with other sensor-based devices and not medical ones; the inclusion phase resulted in the inclusion of 111 articles. Patients who utilise sensor-based devices have several advantages due to rehabilitating a missing component, which marks the accomplishment of a fundamental goal within the rehabilitation program. As technology moves faster and faster forward, the field of medical rehabilitation has to adapt to the time we live in by using technology and intelligent devices. This means changing every part of rehabilitation and finding the most valuable and helpful gadgets that can be used to regain lost functions, keep people healthy, or prevent diseases.


Assuntos
Terapia por Exercício , Reabilitação , Dispositivos Eletrônicos Vestíveis , Humanos
11.
Sensors (Basel) ; 23(20)2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37896489

RESUMO

Hand-function recovery is often a goal for stroke survivors undergoing therapy. This work aimed to design, build, and verify a pneumatic hand training device for its eventual use in post-stroke rehabilitation. The system was built considering prior research in the field of robotic hand rehabilitation as well as specifications and design constraints developed with physiotherapists. The system contained pneumatic airbag actuators for the fingers and thumb of the hand, a set of flex, pressure, and flow sensors, and software and hardware controls. An experiment with the system was carried out on 30 healthy individuals. The sensor readings were analyzed for repeatability and reliability. Position sensors and an approximate biomechanical model of the index finger were used to estimate joint angles during operation. A survey was also issued to the users to evaluate their comfort levels with the device. It was found that the system was safe and comfortable when moving the fingers of the hand into an extension.


Assuntos
Exoesqueleto Energizado , Procedimentos Cirúrgicos Robóticos , Reabilitação do Acidente Vascular Cerebral , Humanos , Reprodutibilidade dos Testes , Desenho de Equipamento , Mãos , Dedos
12.
Front Bioeng Biotechnol ; 11: 1244550, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37849981

RESUMO

Robot-assisted rehabilitation has exhibited great potential to enhance the motor function of physically and neurologically impaired patients. State-of-the-art control strategies usually allow the rehabilitation robot to track the training task trajectory along with the impaired limb, and the robotic motion can be regulated through physical human-robot interaction for comfortable support and appropriate assistance level. However, it is hardly possible, especially for patients with severe motor disabilities, to continuously exert force to guide the robot to complete the prescribed training task. Conversely, reduced task difficulty cannot facilitate stimulating patients' potential movement capabilities. Moreover, challenging more difficult tasks with minimal robotic assistance is usually ignored when subjects show improved performance. In this paper, a control framework is proposed to simultaneously adjust both the training task and robotic assistance according to the subjects' performance, which can be estimated from the users' electromyography signals. Concretely, a trajectory deformation algorithm is developed to generate smooth and compliant task motion while responding to pHRI. An assist-as-needed (ANN) controller along with a feedback gain modification algorithm is designed to promote patients' active participation according to individual performance variance on completing the training task. The proposed control framework is validated using a lower extremity rehabilitation robot through experiments. The experimental results demonstrate that the control scheme can optimize the robotic assistance to complete the subject-adaptation training task with high efficiency.

13.
Sensors (Basel) ; 23(12)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37420707

RESUMO

Caregivers that assist with wheelchair transfers are susceptible to back pain and occupational injuries. The study describes a prototype of the powered personal transfer system (PPTS) consisting of a novel powered hospital bed and a customized Medicare Group 2 electric powered wheelchair (EPW) working together to provide a no-lift solution for transfers. The study follows a participatory action design and engineering (PADE) process and describes the design, kinematics, and control system of the PPTS and end-users' perception to provide qualitative guidance and feedback about the PPTS. Thirty-six participants (wheelchair users (n = 18) and caregivers (n = 18)) included in the focus groups reported an overall positive impression of the system. Caregivers reported that the PPTS would reduce the risk of injuries and make transfers easier. Feedback revealed limitations and unmet needs of mobility device users, including a lack of power seat functions in the Group-2 wheelchair, a need for no-caregiver assistance/capability for independent transfers, and a need for a more ergonomic touchscreen. These limitations may be mitigated with design modifications in future prototypes. The PPTS is a promising robotic transfer system that may aid in the higher independence of powered wheelchair users and provide a safer solution for transfers.


Assuntos
Pessoas com Deficiência , Tecnologia Assistiva , Cadeiras de Rodas , Idoso , Estados Unidos , Humanos , Desenho de Equipamento , Medicare
14.
Biomed Eng Online ; 22(1): 67, 2023 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-37424017

RESUMO

Interest in home-based stroke rehabilitation mechatronics, which includes both robots and sensor mechanisms, has increased over the past 12 years. The COVID-19 pandemic has exacerbated the existing lack of access to rehabilitation for stroke survivors post-discharge. Home-based stroke rehabilitation devices could improve access to rehabilitation for stroke survivors, but the home environment presents unique challenges compared to clinics. The present study undertakes a scoping review of designs for at-home upper limb stroke rehabilitation mechatronic devices to identify important design principles and areas for improvement. Online databases were used to identify papers published 2010-2021 describing novel rehabilitation device designs, from which 59 publications were selected describing 38 unique designs. The devices were categorized and listed according to their target anatomy, possible therapy tasks, structure, and features. Twenty-two devices targeted proximal (shoulder and elbow) anatomy, 13 targeted distal (wrist and hand) anatomy, and three targeted the whole arm and hand. Devices with a greater number of actuators in the design were more expensive, with a small number of devices using a mix of actuated and unactuated degrees of freedom to target more complex anatomy while reducing the cost. Twenty-six of the device designs did not specify their target users' function or impairment, nor did they specify a target therapy activity, task, or exercise. Twenty-three of the devices were capable of reaching tasks, 6 of which included grasping capabilities. Compliant structures were the most common approach of including safety features in the design. Only three devices were designed to detect compensation, or undesirable posture, during therapy activities. Six of the 38 device designs mention consulting stakeholders during the design process, only two of which consulted patients specifically. Without stakeholder involvement, these designs risk being disconnected from user needs and rehabilitation best practices. Devices that combine actuated and unactuated degrees of freedom allow a greater variety and complexity of tasks while not significantly increasing their cost. Future home-based upper limb stroke rehabilitation mechatronic designs should provide information on patient posture during task execution, design with specific patient capabilities and needs in mind, and clearly link the features of the design to users' needs.


Assuntos
COVID-19 , Robótica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Humanos , Assistência ao Convalescente , Pandemias , Alta do Paciente , Extremidade Superior
15.
Biomed Eng Lett ; 13(3): 485-494, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37519872

RESUMO

Injuries involving the nervous system, such as a brachial plexus palsy or traumatic brain injury, can lead to impairment in the functionality of the hand. Assistive robotics have been proposed as a possible method to improve patient outcomes in rehabilitation. The work presented here evaluates the FLEXotendon Glove-III, a 5 degree-of-freedom, voice-controlled, tendon-driven soft robotic hand exoskeleton, with two human subjects with hand impairments and four able-bodied subjects. The FLEXotendon Glove-III was evaluated on four unimpaired subjects, in conjunction with EMG sensor data, to determine the quantitative performance of the glove in applied pinch force, perturbation resistance, and exertion reduction. The exoskeleton system was also evaluated on two subjects with hand impairments, using two standardized hand function tests, the Jebsen-Taylor Hand Function Test and the Toronto Rehabilitation Institute Hand Function Test. The subjects were also presented with three qualitative questionnaires, the Capabilities of Upper Extremities Questionnaire, the Quebec User Evaluation of Satisfaction with Assistive Technology, and the Orthotics Prosthetics User Survey-Satisfaction module. From the previous design, minor design changes were made to the exoskeleton. The quick connect system was redesigned for improved performance, the number of motors was reduced to decrease overall footprint, and the entire system was placed into a compact acrylic case that can be placed into a backpack for increased portability.

16.
Sensors (Basel) ; 23(14)2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37514633

RESUMO

The preliminary test results of a novel robotic hand rehabilitation device aimed at treatment for the loss of motor abilities in the fingers and thumb due to stroke are presented. This device has been developed in collaboration with physiotherapists who regularly treat individuals who have suffered from a stroke. The device was tested on healthy adults to ensure comfort, user accessibility, and repeatability for various hand sizes in preparation for obtaining permission from regulatory bodies and implementing the design in a full clinical trial. Trials were conducted with 52 healthy individuals ranging in age from 19 to 93 with an average age of 58. A comfort survey and force data ANOVA were performed to measure hand motions and ensure the repeatability and accessibility of the system. Readings from the force sensor (p < 0.05) showed no significant difference between repetitions for each participant. All subjects considered the device comfortable. The device scored a mean comfort value of 8.5/10 on all comfort surveys and received the approval of all physiotherapists involved. The device has satisfied all design specifications, and the positive results of the participants suggest that it can be considered safe and reliable. It can therefore be moved forward for clinical trials with post-stroke users.


Assuntos
Exoesqueleto Energizado , Robótica , Reabilitação do Acidente Vascular Cerebral , Acidente Vascular Cerebral , Adulto , Humanos , Pessoa de Meia-Idade , Dedos , Mãos , Adulto Jovem , Idoso , Idoso de 80 Anos ou mais , Ensaios Clínicos como Assunto
17.
IEEE J Transl Eng Health Med ; 11: 282-290, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37275470

RESUMO

This paper presents a twin dual-axis robotic platform system which is designed for the characterization of postural balance under various environmental conditions and quantification of bilateral ankle mechanics in 2 degrees-of-freedom (DOF) during standing and walking. Methods: Validation experiments were conducted to evaluate performance of the system: 1) to apply accurate position perturbations under different loading conditions; 2) to simulate a range of stiffness-defined mechanical environments; and 3) to reliably quantify the joint impedance of mechanical systems. In addition, several human experiments were performed to demonstrate the system's applicability for various lower limb biomechanics studies. The first two experiments quantified postural balance on a compliance-controlled surface (passive perturbations) and under oscillatory perturbations with various frequencies and amplitudes (active perturbations). The second two experiments quantified bilateral ankle mechanics, specifically, ankle impedance in 2-DOF during standing and walking. The validation experiments showed high accuracy of the platform system to apply position perturbations, simulate a range of mechanical environments, and quantify the joint impedance. Results of the human experiments further demonstrated that the platform system is sensitive enough to detect differences in postural balance control under challenging environmental conditions as well as bilateral differences in 2-DOF ankle mechanics. This robotic platform system will allow us to better understand lower limb biomechanics during functional tasks, while also providing invaluable knowledge for the design and control of many robotic systems including robotic exoskeletons, prostheses and robot-assisted balance training programs. Clinical and Translational Impact Statement- Our robotic platform system serves as a tool to better understand the biomechanics of both healthy and neurologically impaired individuals and to develop assistive robotics and rehabilitation training programs using this information.


Assuntos
Robótica , Humanos , Robótica/métodos , Fenômenos Biomecânicos , Tornozelo , Articulação do Tornozelo , Caminhada
18.
Biomimetics (Basel) ; 8(2)2023 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-37366808

RESUMO

When walking with wearable robotic exoskeletons (WRE) in people with spinal cord injury, the distance between the user and the walker is one of the most important perspectives for ensuring safety. The purpose of this study was to clarify the distance between WRE users and four-wheeled walkers (4WW) while walking on level and sloping surfaces. To eliminate the effects of variation in neurological conditions, 12 healthy subjects participated. All participants ambulated using the WRE and the 4WW on level and sloping surfaces. The outcomes were the mean distances between the WRE users and the 4WWs in the level and slope conditions. To examine the influence of uphill and downhill slopes on distance, comparisons were conducted between the uphill or downhill conditions and the respective transitional periods. In the uphill condition, the mean distances were significantly greater than that in the level condition. Conversely, the mean distance moving downhill was significantly shorter than that in the level condition. Changes in the distance between the WRE user and the 4WW might increase the risk of falling forward on an uphill slope and backward on a downhill slope. This study's results will assist in developing a new feedback system to prevent falls.

19.
Front Neurorobot ; 17: 1161187, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37292117

RESUMO

Introduction: Hemiparesis is a common consequence of stroke that severely impacts the life quality of the patients. Active training is a key factor in achieving optimal neural recovery, but current systems for wrist rehabilitation present challenges in terms of portability, cost, and the potential for muscle fatigue during prolonged use. Methods: To address these challenges, this paper proposes a low-cost, portable wrist rehabilitation system with a control strategy that combines surface electromyogram (sEMG) and electroencephalogram (EEG) signals to encourage patients to engage in consecutive, spontaneous rehabilitation sessions. In addition, a detection method for muscle fatigue based on the Boruta algorithm and a post-processing layer are proposed, allowing for the switch between sEMG and EEG modes when muscle fatigue occurs. Results: This method significantly improves accuracy of fatigue detection from 4.90 to 10.49% for four distinct wrist motions, while the Boruta algorithm selects the most essential features and stabilizes the effects of post-processing. The paper also presents an alternative control mode that employs EEG signals to maintain active control, achieving an accuracy of approximately 80% in detecting motion intention. Discussion: For the occurrence of muscle fatigue during long term rehabilitation training, the proposed system presents a promising approach to addressing the limitations of existing wrist rehabilitation systems.

20.
Biomed Eng Lett ; 13(2): 153-163, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37124112

RESUMO

Cervical spinal cord injury (SCI) can significantly impair an individual's hand functionality due to the disruption of nerve signals from the brain to the upper extremity. Robotic assistive hand exoskeletons have been proposed as a potential technology to facilitate improved patient rehabilitation outcomes, but few exoskeleton studies utilize standardized hand function tests and questionnaires to produce quantitative data regarding exoskeleton performance. This work presents the human subject case study evaluation of the FLEXotendon Glove-III, a 5 degree-of-freedom voice-controlled, tendon-driven soft robotic assistive hand exoskeleton for individuals with SCI. The exoskeleton system was evaluated in a case study with two individuals with SCI through two standardized hand function tests namely, the Jebsen-Taylor Hand Function Test and the Toronto Rehabilitation Institute Hand Function Test and three questionnaires (Capabilities of Upper Extremities Questionnaire, Orthotics Prosthetics Users Survey, Quebec User Evaluation of Satisfaction with Assistive Technology). Minor design changes were made to the exoskeleton: integrated fingertip force sensors to sense excessive grasp force, a quick connect system to expedite the exoskeleton glove swapping process between users, compact tendon tension sensors to measure tendon force for admittance control, and a redesigned smartphone app to encompass all aspects of exoskeleton use.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...